Plug size and torque chart (continued)
Item O-ring plug Wrench size Torque
F0100
9/16 - 18UNF 1/4 internal hex 40 N•m [30 lbf•ft]
F0150 (060)
1-1/16 - 12 UN (Radial endcap) 9/16 internal hex
95 N•m [70 lbf•ft]
F0150 (080, 110,
160, 210, 250)
115 N•m [85 lbf•ft]
G0050
5/16 - 24UNF (SAE and DIN flange) 1/8 internal hex 8 N•m [5 lbf•ft]
G0055
7/16 - 20UNF (Cartridge only/not shown) 3/16 internal hex 8 N•m [5 lbf•ft]
G0060 (060, 080)
7/8 - 14UN 3/8 internal hex 70 N•m [52 lbf•lb]
G0060 (110, 160)
1-1/16 - 12UN 9/16 internal hex 70 N•m [52 lbf•lb]
G0060 (210, 250)
1-5/16 - 12UN 5/8 internal hex 70 N•m [52 lbf•lb]
K0030
M18 - 1.5 24 mm hex 67 N•m [49 lbf•ft]
L00**
M18 - 1.5 24 mm hex 67 N•m [49 lbf•ft]
F0160
9/16-18 UNF (Axial endcap, not shown) 1/4 internal hex 40 N•m [30 lbf•ft]
Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Torque chart
©
Danfoss | August 2018 AX00000025en-US0504 | 67