EasyManua.ls Logo

Danfoss MCA 121 - Class ID 0 x0 F Parameter Object

Danfoss MCA 121
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Attrib
ute
Access
Rule
Name Data Type Description of Attribute Parameter
in
frequency
converter
9 Get Link List ARRAY OF UINT Link List between internal and all according external interfaces -
Table 8.11 Instance Attributes
Service Code Supported Service Name Description of Service
Class Instance
01h Yes Yes Get_Attribute_All Returns a predefined listing of this objects attributes
0Eh Yes Yes Get_Attribute_Single Returns the contents of the specified attribute.
10h - Yes Set_Attribute_Single Modifies a single attribute.
43h - Yes Get_and_Clear Gets then clears the specified attribute (Interface
Counters or Media Counters).
Table 8.12 Services supported
Appendix MCA 121 EtherNet/IP
MG.90.J3.02 - VLT
®
is a registered Danfoss trademark 51
8 8