Environmental
Testing Criteria (continued)
Electrical/Electromagnetic
Description Applicable standard Comment
EMC emission ISO 13766, SAE J1113-13 Electromagnetic compatibility for earth moving
machinery.
EMC immunity ISO 13766 Electromagnetic compatibility for earth moving
machinery.
Electrostatic discharge EN 60-1 000-4-2
Auto electrical transients ISO 7637-2, ISO 7637-3
Short circuit protection Danfoss test Inputs and outputs survive continuous short
circuit. Normal function resumes when short is
removed.
Reversed polarity protection Danfoss test Survives reverse polarity at supply voltage for at
least five minutes.
Housing
The TMC housing features a snap together assembly that is tamper-proof. Once assembled at the
factory, the housing cannot be opened for service.
Opening the TMC housing will void the factory warranty.