Technical Information Transit Mixer Controller (TMC)
11061324 • Rev CA • Sep 2013
9
Product Specifications
Environmental
Testing Criteria
General PLUS+1 Module Ratings
Description Units Minimum Maximum Comment
Operating temperature ˚C [˚F] -40 [-40] 70 [158]
Storage temperature ˚C [˚F] -40 [-40] 85 [185]
Allowable module supply voltage Vdc 9 36
Module sensor supply voltage Vdc 4.88 5.12 All current returns must be directly wired
to the machine ground to reduce any
voltage losses to the sensor power line.
Failure to comply may result in a sensor
power voltage lower than the specified
minimum.
Analog input voltage levels Vdc 36
Allowable output load current
(per pin)
A 8
TMC allowable total output current A 11. 5
IP rating
(with mating connector attached)
IP 69K (front)
IP 67* (rear)
CE rating CE compliant
* PLUS+1 module IP 67 rating is only valid when the module mating connector is in place and unused connector pin positions
have sealing plugs installed.
Testing Criteria
Climate Environment
Description Applicable standard Comment
Storage temperature IEC 60068-2-1, test Ab, IEC
60068-2-2 test Bb
Operating temperature IEC 60068-2-1, test Ab, IEC
60068-2-2 test Bd
Thermal cycle IEC 60068-2-2, test Na, IEC
60068-2-38 (partial)
Humidity IEC 60068-2-78, IEC
60068-2-30 test Db
Damp heat steady state and cyclic.
Degree of protection IEC 60529
Chemical Environment
Description Applicable standard Comment
Salt mist IEC 60068-2-58 test Kb
Chemical resistance ISO 16750-5
Mechanical Environment
Description Applicable standard Comment
Vibration IEC 60068-2-6 test Fc,
IEC6008-2-64 test Fh
Bump IEC 60068-2-29 test Eb
Shock IEC 60068-2-27 test Ea
Free fall IEC 60068-2-32 test Ed