EasyManua.ls Logo

Danfoss PVG 32

Danfoss PVG 32
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PVLA, suction valve (fitted in PVB)
PVLA, suction valve
Symbol Description Code number
Suction valve for port A and/or B. 157B2001
Plug for connecting the nonactive port to tank, when using a
single acting spool.
157B2002
PVLP, shock and suction valve (fitted in PVB)
PVLP, shock/ and anti-cavitation valves
Code no.
157B....
2032 2050 2063 2080 2100 2125 2140 2150 2160 2175 2190
Settings bar 32 50 63 80 100 125 140 150 160 175 190
[psi] [460] [725] [914] [1160] [1450] [1813] [2031] [2175] [2320] [2538] [2755]
Code no.
157B....
2210 2230 2240 2250 2265
2280
2300 2320 2350 2380 2400
Settings bar 210 230 240 250 265 280 300 320 350 380 400
[psi] [3045] [3335] [3480] [3625] [3845] [4061] [4351] [4641] [5075] [5511] [5801]
PVLP, shock and suction valve
Symbol
Description
Shock and suction valve for port A and/or B.
(Not adjustable).
Lifetime 200.000 actuations.
Technical Information
PVG 32 Proportional Valve Group
Modules symbols, description and code numbers
56 |
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802

Table of Contents

Other manuals for Danfoss PVG 32

Related product manuals