EasyManua.ls Logo

Danfoss PVG 32

Danfoss PVG 32
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Size C: Size D:
Example 2
Size E:
Examples of how to use the characteristics for pressure control spools
Example 1: Determining the oil flow Example 2: Determining the spool size
Given:
Spool type B
Pressure setting P
P
: 160 bar [2320 psi]
Load pressure, LS
A/B
: 100 bar [1450 psi]
Result:
Oil flow = 75 l/min [19.8 US gal/min]
Given:
Max. oil flow, Q
A/B
: 90 l/min [23.8 US gal/min]
Pressure setting P
P
: 150 bar [2175 psi]
Load pressure, P
LSA
: 125 bar [1810 psi]
Result: D spool
(see Pressure CS flow characteristics, size D)
Normally a smaller spool can be chosen with pressure control. It is our experience that the spool can be
one size smaller than with normal flow control.
Technical Information
PVG 32 Proportional Valve Group
Technical characteristics
42 |
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802

Table of Contents

Other manuals for Danfoss PVG 32

Related product manuals