EasyManuals Logo
Home>Danfoss>Control Unit>PVG 32

Danfoss PVG 32 Technical Information

Danfoss PVG 32
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
The figures in the table have been calculated according to the following expressions:
PVLP ≤150 bar: LS
A/B
≤ 0.8 × P
PVLP
PVLP >150 bar: P
PVLP
- LS
A/B
≥ 30 bar.
Max. pressure setting of LS
A
and LS
B
valves relative to PVLP shock valve
Pressure for PVLP Max. for LS
A/B
Min. for LS
A/B
bar [psi] bar [psi] bar [psi]
32 [460] - - 30 bar] [435 psi]
50 [725] 40 [580]
63 [914] 50 [720]
80 [1160] 64 [930]
100 [1450] 80 [1160]
125 [1813] 100 [1450]
140 [2031] 112 [1625]
150 [2175] 120 [1740]
160 [2320] 130 [1885]
175 [2838] 145 [2100]
190 [2755] 160 [2320]
210 [3045] 180 [2610]
230 [3335] 200 [2900]
240 [3480] 210 [3045]
250 [3625] 220 [3190]
265 [3843] 235 [3408]
280 [4061] 250 [3625]
300 [4351] 270 [3915]
320 [4641] 290 [4205]
350 5075 320 4641
380 5511 350 5075
400 5801 370 5366
Technical Information
PVG 32 Proportional Valve Group
Order specification
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802 | 71

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals