The figures in the table have been calculated according to the following expressions:
•
PVLP ≤150 bar: LS
A/B
≤ 0.8 × P
PVLP
•
PVLP >150 bar: P
PVLP
- LS
A/B
≥ 30 bar.
Max. pressure setting of LS
A
and LS
B
valves relative to PVLP shock valve
Pressure for PVLP Max. for LS
A/B
Min. for LS
A/B
bar [psi] bar [psi] bar [psi]
32 [460] - - 30 bar] [435 psi]
50 [725] 40 [580]
63 [914] 50 [720]
80 [1160] 64 [930]
100 [1450] 80 [1160]
125 [1813] 100 [1450]
140 [2031] 112 [1625]
150 [2175] 120 [1740]
160 [2320] 130 [1885]
175 [2838] 145 [2100]
190 [2755] 160 [2320]
210 [3045] 180 [2610]
230 [3335] 200 [2900]
240 [3480] 210 [3045]
250 [3625] 220 [3190]
265 [3843] 235 [3408]
280 [4061] 250 [3625]
300 [4351] 270 [3915]
320 [4641] 290 [4205]
350 5075 320 4641
380 5511 350 5075
400 5801 370 5366
Technical Information
PVG 32 Proportional Valve Group
Order specification
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802 | 71