EasyManuals Logo

Danfoss VLT 2800 User Manual

Danfoss VLT 2800
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
349 Speed comp delay
(SPEED COMP DELAY)
Value:
0 ms - 100 ms
10 ms
Function:
In this parameter the user can set the SYSTEM's delay
time (Sensor, PLC, etc.). If you are running speed-
compensated stop, the delay time at different frequen-
cies has a major influence on the way in which you
stop.
Description of choice:
The factory setting is 10 ms. This means that it is as-
sumed that the total delay from the Sensor, PLC and
other hardware corresponds to this setting.
NB!
Only active for speed-compensated stop.
94 MG.27.E2.02 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT 2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 2800 and is the answer not in the manual?

Danfoss VLT 2800 Specifications

General IconGeneral
Frequency50/60 Hz
EnclosureIP20
Input Voltage200-240V AC
Output Power Range0.37-2.2kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Communication InterfaceRS485
Operating Temperature-10°C to +40°C
Storage Temperature-25°C to +65 °C
Relative Humidity5 - 95% RH, non-condensing
Output Voltage0 - 100% of supply voltage

Related product manuals