Ordering Numbers: Brake Resistors
Mains 525-690 VAC (T7-HP)
VLT AQUA Drive
Selected resistor
Standard IP 20
Max. brake tor-
que with R
rec
Duty Cycle 10% Duty Cycle 40%
Size:
P
motor
R
min
R
br,nom
R
rec
P
br avg
Order no. Period R
rec
P
br avg
Order no. Period
[kW] [] [] [] [kW] 130Bxxxx [s] [] [kW] 130Bxxxx [s] %
P37K 37 22.5 32.1 20 52 2118 600 20 32 2118 600 110 (110)
P45K 45 22.5 26.4 15 64 2119 600 15 39 2119 600 110 (110)
P55K 55 18 21.6 15 76 2120 600 15 47 2120 600 110 (110)
P75K 75 13.5 15.6 9.8 104 2121 600 9.8 64 2121 600 110 (110)
P90K 90 8.8 13 9.8 126 2122 600 9.8 77 2122 600 110 (110)
P110 110 8.8 10.7 7.3 153 2123 600 7.3 93 2123 600 110 (110)
P132 132 6.6 8.9 4.7 185 2124 600 4.7 113 2124 600 110 (110)
P160 160 6.6 7.3 4.7 224 2125 600 4.7 137 2125 600 110 (110)
P200 200 4.2 5.9 3.8 147 2X2126 600 3.8 90 2X2126 600 110 (110)
P250 250 4.2 4.7 2.6 173 2X2127 600 2.6 106 2X2127 600 110 (110)
P315 315 3.4 3.7 2.6 212 2X2128 600 2.6 130 2X2128 600 108 (110)
P400 355 2.3 3.3 2.6 72 2x1062 300 - - - - 110 (110)
P450 400 2.3 2.9 2.6 72 2x1062 300 - - - - 110 (110)
P500 500 2.1 2.3 2.3 90 2x1063 300 - - - - 110 (110)
P560 560 1.9 2.1 2.1 100 2x1064 300 - - - - 110 (110)
P630 630 1.7 1.9 - - - - - - - - -
P710 710 1.5 1.7 - - - - - - - - -
P800 800 1.3 1.5 - - - - - - - - -
P900 900 1.2 1.3 - - - - - - - - -
P1M0 1000 1.2 1.3 - - - - - - - - -
VLT
®