EasyManuals Logo

Danfoss VLT AutomationDrive FC 300 Instruction Manual

Danfoss VLT AutomationDrive FC 300
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
2-28 Gain Boost Factor
Range: Function:
1.00* [1.00 - 4.00 ] Only active in flux closed-loop. The function ensures a smooth transition from torque control mode
to speed control mode when the motor takes over the load from the brake.
Figure 4.1: Brake release sequence for hoist mechanical brake control
I)
Activate brake delay
: The adjustable frequency drive starts again from the
mechanical brake engaged
position.
II)
Stop delay
: When the time between successive starts is shorter than the setting in par. 2-24
Stop Delay
, the adjustable frequency drive
starts without applying the mechanical brake (e.g., reversing).
4 How to Program
VLT
®
AutomationDrive FC 300 Instruction
Manual
4-14
MG.33.AG.22 - VLT
®
is a registered Danfoss trademark
4

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300
CategoryDC Drives
LanguageEnglish

Related product manuals