3-80 Jog Ramp Time
Range: Function:
3.00 s
*
[0.05 - 3600.00 s]
A linear ramp applicable when Jog is activated. See par. 5-1*, selection [14].
Ramp up time = Ramp down time.
Jog Ramp time starts upon activation of a jog signal via a selected digital input or serial communication port.
3-81 Quick Stop Ramp Time
Range: Function:
3.00 s
*
[0.05 - 3600.00 s]
A linear ramp applicable when Q-stop is activated. See par. 5-1*, selection [4].
VLT
p
Micro Drive FC 51 4. Parameter Descriptions
MG.02.C4.02 - VLT
p
is a registered Danfoss trademark