NB!
Parameters are only active when par. 8-01,
Control SIte
, is set to
Digital and control word
[0].
8-50 Coasting Select
Option: Function:
Select control of coasting function via digital input and/or bus.
[0] Digital Input Activation via a digital input.
[1] Bus Activation via serial communication port.
[2] LogicAnd Activation via serial communication port and a digital input.
[3]
*
LogicOr Activation via serial communication port or a digital input.
8-51 Quick Stop Select
Option: Function:
Select control of quick stop function via digital input and/or bus.
[0] Digital Input Activation via a digital input.
[1] Bus Activation via serial communication port.
[2] LogicAnd Activation via serial communication port and a digital input.
[3]
*
LogicOr Activation via serial communication port or a digital input.
8-52 DC Brake Select
Option: Function:
Select control of DC brake via digital input and/or bus.
[0] Digital Input Activation via a digital input.
[1] Bus Activation via serial communication port.
[2] LogicAnd Activation via serial communication port and a digital input.
[3]
*
LogicOr Activation via serial communication port or a digital input.
8-53 Start Select
Option: Function:
Select control of start function via digital input and/or bus.
[0] Digital Input Activation via a digital input.
[1] Bus Activation via serial communication port.
[2] LogicAnd Activation via serial communication port and a digital input.
[3]
*
LogicOr Activation via serial communication port or a digital input.
8-54 Reversing Select
Option: Function:
Select control of reversing function via digital input and/or bus.
[0] Digital Input Activation via a digital input.
[1] Bus Activation via serial communication port.
[2] LogicAnd Activation via serial communication port and a digital input.
[3]
*
LogicOr Activation via serial communication port or a digital input.
8-55 Set-up Select
Option: Function:
Select control of set-up selection via digital input and/or bus.
[0] Digital Input Activation via a digital input.
[1] Bus Activation via serial communication port.