119
MG.10.J8.02 – VLT is a registered Danfoss trade mark
Programmable SyncPos motion controller
Software Reference
INKEY
With the INKEY command it is possible to read a
key signal from the VLT keyboard. The parameter
entered with INKEY determines whether the program
waits unconditionally for a key signal, for a certain
period of time or not at all.
One key signal is read in per successful INKEY
command respectively. To input a string of charac-
ters it is necessary to repeat the INKEY command
(p<>0) in a loop until no further key signals exist.
Summary
Read in a key signal
Syntax
INKEY (p)
Parameter
p is the maximum waiting time, defined ...
p = 0 wait for key code
p > 0 wait of max. p milli-seconds
p < 0 no wait for key code
Return value
key code for the received character
resp –1 in case no character available
Following key codes are sent back, as long as the
key is pressed. If more than one key were pressed
simultaneously the corresponding sum of the
values will be sent back:
key: value:
MENU 1
QUICK MENU 2
DISPLAY / STATUS 8
OK 16
CANCEL 32
CHANGE DATA 128
-key 256
-key 512
-key 1024
-key 2048
START 4096
FWD. REV. 8192
JOG 16384
STOP / RESET 32768
Combinations send the corresponding values:
OK and CANCEL 48
START and -key 4608
NB!
The keys keep their VLT-functions, unless they
are disabled in Parameter 014–017.
A negative parameter must be given in brackets.
Command group
I/O
Cross Index
PRINT
Chapter Fundamentals of the SyncPos program
Syntax-Example
input = INKEY 0
/* wait until key signal is read */
input = INKEY 5000
/* wait max. 5 seconds to input */
input = INKEY (-1)
/* do not wait for input */
Program sample
INKEY_01.M
EXIT_01.M, WHILE_01.M

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT5000 SyncPos and is the answer not in the manual?

Danfoss VLT5000 SyncPos Specifications

General IconGeneral
CategoryController
Frequency50/60 Hz
SeriesVLT5000
Control MethodVector control
CommunicationCANopen
Enclosure RatingIP20
Storage Temperature-25°C to 70°C
AltitudeUp to 1000m above sea level
Humidity5% to 95% (non-condensing)

Related product manuals