APP-control v10.x
8.1.3 Operating time
You can configure a default run-time via SMS. If you switch on the heater by
APP, SMS or Call, the heater will use this run-time. If you switch the heater by
APP or SMS, you can define a run-time of 10, 20, 30, 40, 50 or 60 minutes. The
heater will run for this time once and than uses the default value again.
E-BUS only
The APP-control queries the operating-time from the vehicles board-computer.
If the operating-time can't be queried, the default value will be used.
8.2 Alarm function
The APP-control is equipped with an alarm input which can be connected to an
existing alarm system.
After connecting the power supply to the APP-control, the voltage level on the
alarm input will be stored (0 or +12V). As soon as this level changes, the alarm
will be triggered and all stored numbers are informed by call and SMS.
11 - 32
Factory installed alarmsystems are often integrated into
the vehicles bus-system. Further information about how to
connect these system can be found at our website: