EasyManua.ls Logo

Dantherm HPP-i 8 - Page 37

Dantherm HPP-i 8
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
1007332 ISSUE 1
MODEL UNITS HPP-i 18 HPP-i 24 HPP-i 30
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity kW 21.0 27.5 36.0
COP range 14.8-6.4 15.0-6.8 14.8-6.0
Average COP at 50% Speed 10.3 10.3 10.2
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity kW 14.5 18.0 23.9
COP range 7.1-4.6 7.5-4.6 7.5-4.6
Average COP at 50% Speed 6.3 6.3 6.3
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity
kW 9.5 11.9 16.0
TECHNICAL SPECIFICATIONS
Operating air temperature °C -10°C to 43°C
Water heat temperature set range °C 18°C to 40°C
Water cool temperature set range °C 12°C to 30°C
POWER SUPPLY 400V Three Phase 50Hz
Rated input power kW 0.41-3.15 0.48-3.91 0.64-5.20
Rated input current A 0.59-4.56 0.69-5.66 0.92-7.53
Maximum input current A 5.8 7 9.5
Rated RCD type B mA 30 30 30
Rated Fuse aM / MCB type C A 10 10 16
Sound pressure level at 10m dB(A) 20.4-33.7 23.0-34.4 22.1-34.2
Recommended water flow rate m
3
/h 8.0-10.0 10.0-12.0 12.0-18.0
Pressure drop m/kPa 0.61/6.0 0.77/7.5 0.85/8.5
Pool water connections Inches 1½” or 50mm Female
GENERAL DATA
Net dimensions (w x d x h) mm 954x429x755 1084x429x948 1154x539x948
Packed dimensions (w x d x h) mm 1040x445x655 1130x445x985 1200x555x985
Net weight kg 68 93 120
HERMETIC SYSYEM
Refrigerant charge R32 kg 1.2 2.0 2.7
Minimum area requirement m2 12.3 34.0 62.0
NOTES: Heat pump performance parameters are subject to change wiout notice. Always refer to e
nameplate. Global warming potential (GWP) R32 - 675.
The data is subject to modification wiout prior warning.