EasyManuals Logo

Datalogic Magellan 2200VS User Manual

Datalogic Magellan 2200VS
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #271 background imageLoading...
Page #271 background image
Other UPC/EAN Options
Product Reference Guide 261
Addon Timer
When addons have been selected as optional, this feature sets the duration
of time that the scanner can unsuccessfully look for an addon before pro-
ceeding to read a bar code. Timer duration is specified in 10ms incre-
ments.
To set the Addon Timer:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET ADDON TIMER DURATION below. You’ll
need to cover any unused bar codes on this and the facing page to
ensure that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired Addon Timer Duration. The selectable range is 1-
10, which is the timeout in 10-millisecond increments. Pad all sin-
gle and double digit numbers with leading zeroes to yield a three-
digit entry (001-010).
Examples:
001 = 10ms
003 = 30ms
008 = 80ms
Complete the programming sequence by scanning the SWITCH bar
code.
SET ADDON TIMER DURATION

Table of Contents

Other manuals for Datalogic Magellan 2200VS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 2200VS and is the answer not in the manual?

Datalogic Magellan 2200VS Specifications

General IconGeneral
Decoding standards-1D + GS1 DataBar, -GS1 DataBar Expanded Stacked, -GS1 DataBar Stacked, -GS1 DataBar Stacked Omnidirectional.
Standard interfacesUSB, RS-232
Dimensions (WxDxH)152 x 152 x 97 mm
Product colorGray
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight1100 g

Related product manuals