EasyManuals Logo

Datalogic Magellan 2200VS User Manual

Datalogic Magellan 2200VS
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #298 background imageLoading...
Page #298 background image
288 Magellan
®
2200VS/2200VS and 2300HS/2300HS
Code 39 Check Character Calculation
Enables/disables calculation and verification of an optional Code 39 check
character. When disabled, any check character in label is treated as a data
character.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
CODE 39 CHECK CHARACTER CALCULATION = DISABLE
CODE 39 CHECK CHARACTER CALCULATION = ENABLE
NOTE
If check calculation is disabled, the risk is increased that a misread
can occur.
In particular, if you are using variable length stitching, it is important to
use check character calculation to prevent misreads.

Table of Contents

Other manuals for Datalogic Magellan 2200VS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 2200VS and is the answer not in the manual?

Datalogic Magellan 2200VS Specifications

General IconGeneral
Decoding standards-1D + GS1 DataBar, -GS1 DataBar Expanded Stacked, -GS1 DataBar Stacked, -GS1 DataBar Stacked Omnidirectional.
Standard interfacesUSB, RS-232
Dimensions (WxDxH)152 x 152 x 97 mm
Product colorGray
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight1100 g

Related product manuals