EasyManuals Logo

Datalogic Magellan 83 Technical Guide

Datalogic Magellan 83
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Motion Test
Technical Guide 4-3
Motion Test
This test verifies that the scale will not ‘zero’ when the weighing surface of
the scanner/scale is in motion.
1. Verify that the Yellow LED
1
is on and the Remote Display reads
0.000 kilograms.
2. Press lightly on the weigh platter of the scanner/scale with one hand
and at the same time press and release the Zero Push Button on the
operator’s panel. The Yellow LED should turn Off and the Remote
Display should not display 0.000 kilograms.
3. Remove your hand from the weighing platform and verify that the
Yellow LED is On and the Remote Display reads 0.000 kilograms.
1. Yellow LED indications can be configured via feature programming and may not be enabled for
certain functions.

Table of Contents

Other manuals for Datalogic Magellan 83

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 83 and is the answer not in the manual?

Datalogic Magellan 83 Specifications

General IconGeneral
BrandDatalogic
ModelMagellan 83
CategoryBarcode Reader
LanguageEnglish

Related product manuals