4-6 Magellan
®
8300/8400
8. The Yellow LED will extinguish for approximately 10 seconds and
the Remote Display will alternately display and
until the scale is ready to proceed.
9. If the calibration was successful, the speaker sounds a single tone,
the Scale Status LED begins blinking again, and “End-” appears in
the Remote Display.
10. If the calibration was not successful, the speaker will sound five
tones indicating a scale failure, and the Scale Status LED will blink
twice, strobe (fast blinks) and then continually repeat this sequence
until reset. Remove all weight from the Weigh Platter, and repeat
the procedure starting with step
7.
11. Press the Zero Push Button again to permanently store the calibra-
tion data and exit Calibration Mode. You have completed the cali-
bration of the scanner/scale. The unit’s calibration must now be
verified as required by state and/or local weights and measures regu-
lations. The verification procedure must be performed to assure that
a scale will pass Weights and Measures requirements before it is
placed into commercial/retail service.
You have completed the scale calibration procedure. You must now con-
tinue with the calibration verification tests to complete the scale’s calibra-
tion.

Table of Contents

Other manuals for Datalogic Magellan 83

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 83 and is the answer not in the manual?

Datalogic Magellan 83 Specifications

General IconGeneral
BrandDatalogic
ModelMagellan 83
CategoryBarcode Reader
LanguageEnglish

Related product manuals