EasyManua.ls Logo

Datalogic Matrix-2000 - Input and Output Connection Schematics; Input Signal Configurations and Features; Output Signal Configurations and Features

Datalogic Matrix-2000
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MATRIX-2000™ QUICK GUIDE
7
Input / Output Connections:
Inputs
USER INTERFACE
OUT
MATRIX
V
CC
A
Vext
B
GND
V
+
~
~
+
-
I
in
30 Vdc Max.
Input PNP command using external power
USER INTERFACE
MATRIX
V
CC
A
B
V
+
~
~
+
-
9
25
OUT
GND
GND
V
S
Input PNP command using Matrix-2000
power
USER INTERFACE
VS
MATRIX
A
Vext
B
V
+
V
CC
~
~
+
-
GND
OUT
30 Vdc Max.
Input NPN command using external power
USER INTERFACE
VS
MATRIX
A
B
GND
V
+
V
CC
~
~
+
-
GND
9
OUT
25
Input NPN command using Matrix-2000
power
The electrical features of the two inputs are:
INPUT | V
AB
| Min. | V
AB
| Max. I
IN
Max
.
Open 0 V 2 V 0 mA
Closed 4.5 V 30 V 10 mA
Outputs
MATRIX
USER INTERFACE
Vext
30 Vdc max
+
-
I
Load
V
Out
Open collector output connection
The electrical features of the three outputs are the
following:
OUTPUT I
Load
V
Out
Open 0 mA 30 Vdc Max
Closed 10 mA 1.8 Vdc Max
P
D
= V
out
× I
load
= 170 mW Max.