Systems Manual 57
Wait Time for
ACK
This setting defines a time period allowed once the scanner has sent
data to the Base Station for that Base Station to send an acknowledge-
ment (ACK) back to the scanner, signalling receipt of the data. This fea-
ture is used to streamline the scanning speed of your system.
The range for this delay is 0.08 - 2.55 seconds in 10ms increments.
Feature is applicable to scanner and Base Station.
NOTE
Remember, programming changes to the Base Sta-
tion have no effect until the new configuration is
downloaded via the feature Transmit Scanner Con-
figuration to Base Station on page 33.
NOTE
Selecting longer values for this feature will
decrease the battery life between charges.
SET -------------------------------------------
Set Wait Time for ACK
Scan three digits representing the desired delay using the Num-
ber Pad in Appendix B. Be sure the number is padded with lead-
ing zeros (example: 008 = 80ms, 025 = 250ms, 100 = 1 second,
etc.), then scan the END bar code.
END ------------------------------------------