Anti-vibration shock absorbers together with fixing brackets are recommended in applications with particularly
strong vibrations to reduce the impact of the vibrations.
Fig 23 - Fixing brackets
Fig 23 - page 26 and table below show the recommended mounting positions according to the safety light curtain
length.
Fig 24 - Dimensions (mm)
V
ERSION L
(
mm
)
A
(
mm
)
B
(
mm
)
C
(
mm
)
015 216.3 108 54 -
030 366.2 216 75 -
045 516.3 316 100 -
060 666.2 366 150 -
075 816.3 466 175 -
090 966.2 566 200 -
105 1116.2 666 225 -
120 1266.3 966 150 483
135 1416.2 1066 175 533
150 1566.3 1166 200 583
165 1716.3 1266 225 633
180 1866.3 1366 250 683