PRINTHEAD CLEANING
Controls the printhead cleaning routine.
CLEAN HEAD SCHEDULE
000 in. (* 1000)
Specifies the inch (or centimeter) count to reach before prompting a printhead
cleaning. If the number specified is exceeded three times, the printer will fault until
cleaning is initiated.
Notes: The default value (zero) disables this function. Also, the number specified is
multiplied by one thousand.
CLEAN HEAD COUNTER
0 in.
Indicates the number of inches (or centimeters) since printhead cleaning was last
initiated.
RESET COUNTER
Allows the clean head counter to be set to zero
CLEAN HEAD NOW
Initiates printhead cleaning and resets the Clean Head Counter.
Notes:
Remove ribbon, if installed.
Enter Menu Mode / Media Settings / Media Type and set the printer for Direct Thermal.
Ensure that full width media is installed.
See Section 6.1 for detailed instructions.

Table of Contents

Other manuals for Datamax Mark II M-4206

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax Mark II M-4206 and is the answer not in the manual?

Datamax Mark II M-4206 Specifications

General IconGeneral
Print Resolution203 dpi
TypeLabel Printer
Print MethodThermal Transfer
Max Print Speed6 inches per second
Memory16 MB SDRAM, 8 MB Flash
InterfacesUSB, Serial, Parallel
Media Width4.5 inches
Media Length0.25" to 99"
Max Print Width4.25 inches (108 mm)