EasyManua.ls Logo

dB Technologies SUB 915 - 2 First Power-Up

dB Technologies SUB 915
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Normal Reversed
Subwoofer
Polarity
Output
Xover/Link
Xover
MODE
100
70
80
110
90
100
70
80
110
90
Xover/Link [Hz]
Link
MODE
2,5
3,5
1,5
3,0
2,0
4,0
1,0
4,5
0
Service/
User
Subwoofer
Delay
[ms]
max
0dB
Input
Sens.
SUB 915 - SUB918 Code 420120322 REV. 1.0
The package of SUB 915 / SUB 918 subwoofer contains:
915 or 918 subwoofer
POWERCON TRUE1 power cable
quick start user manual and warranty documents in hard copy
2. FIRST POWER-UP
CONFIGURATION AND OPTIMISATION
The subwoofer will turn on after inserting, turning and connecting the
powerCON TRUE1® connector to the power supply.
For subwoofer use optimisation in given congurations, the control panel
displays the following:
Xover/Link [Hz]:
1. Link (the signal present at OUTPUTS is the one applied to the woofer)
2. Xover (the signal present at OUTPUTS is ltered with a crossover
frequency of 120 Hz, for daisy chain to a speaker, such as B-HYPE and
OPERA)
Subwoofer Polarity:
1. Normal (audio signal normal polarity)
2. Reverse (reverse polarity, useful for wavefront optimisation through
acoustic wave phase reversal)
Subwoofer Delay:
It is possible to select the applicable delay for various congurations,
according to what is stated on the silk-screen print.
Before power-up, set Input Sensitivity level selector to 0 dB