Accumulator
1. Roles: It removes the liquid refrigerant from the evaporator completely to send only the pure gas refrigerant to the compressor.
A liquid refrigerant to the compressor can cause its overload.
2. Structure:
liquid
liquid
Inhaling Part of the
Compressor
The liquid refrigerant
which is vaporized from
the evaporator will flow
into the accumulator. It
will be vaporized there
before being sent to the
compressor.
Gas Refrigerant