Delem
V1204, 2.16
Parameter 13:
Indexing
Range : 0 - 1
Unit : -
Default : 1
Function
Each time the supply voltage is switched on, the reference position must be passed. This can
be done in two ways:
0 = no reference encoder used, the actual backgauge position will be memorized after power
down.
1 = automatic reference passing, the motor will be controlled after pushing the start button.
Parameter 14:
Reference correction input
Range : 0 - 1
Unit : -
Default : 0
Function
When set to 1, the ‘RFC’ input (ReFerence Correction) input is enabled. When this input is
active, the programmed position (Xm) will be copied to the actual position (Xp).
Parameter 15:
Reference position
Range : 0 - 9999
Unit : mm
Default : 100
Function
This position is assumed when the reference has passed. The reference encoder must generate
a pulse from low to high on the reference input.
Parameter 16:
RSD switch mounted
Range : 0 - 1
Unit : -
Default : 1
Function
0 = System 1: standard reference search system without Reference Search Direction switch
(RSD-switch).
1 = System 2: reference search system with RSD-switch