Delem
V1204, 2.15
Parameter 06:
Minimum backgauge position
Range : 0 - 9999
Unit : mm
Default : 0
Function
Minimum backgauge position. The axis will never be controlled to a lower position than
programmed here.
Parameter 07:
Spindle allowance
Range : 0 - 1
Unit : -
Default : 1
Function
0 = one-side positioning
1 = two-side positioning
Note: One-side positioning is also possible with a servo drive (drive type = 3)
The one-side positioning can be selected to overcome mechanical tolerances with two side
positioning. In case of one-side positioning the positioning direction is from a larger to a
smaller position. See also section 2.3 about drive types.
Parameter 08:
IP tolerance
Range : 0.0 - 9.99
Unit : millimetres
Default : 0.10
Function
The "in-position output" (IP) becomes active if the difference between the actual position and
the programmed position is smaller than this tolerance.
Parameter 09:
Display correction enabled
Range : 0 - 1
Unit : -
Default : 0
Function
Enables correction of then displayed Xp when axis is in position. When this option is enabled,
deviation of Xp within the margins of the in position tolerance (08) are not shown.

Other manuals for Delem DAC-310