Parameter 61:
Angle prestop negative
Range : 0 - 99
Unit : AD value
Default : 0
Function
This parameter has the same definition as parameter "Angle Prestop Positive" but
only in the negative direction of the angle adjustment (smaller angle).
Parameter 65:
Gap control
Range : 0 - 2
Unit : -
Default : 0
Function
Program one of three possible Gap control modes.
0 = No gap control/watch
1 = Gap watch
2 = Gap control
In case of 1 and 2, the following I/O is used:
• digital outputs G+ and G- (only system 2)
• analog input GFB.
Parameter 66:
Gap correction
Range : 0 - 1
Unit : -
Default : 0
Function
When enabled, the backgauge position will be corrected. Needed for constructions where the
gap influences the backgauge position.
Parameter 67: Minimum Gap
Range : 0.00 - 9.99
Unit : mm
Default : 2.5
Function
The minimum possible gap. Only valid when gap control is enabled.