Dell Data Domain DD9500 - DD9500 and DD9800 I;O Module Slot Assignments

Dell Data Domain DD9500
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 14 Location of NVRAM and I/O modules (continued)
2. I/O modules—slots 1 to 11 (See the I/O module slot assignments table.)
Note
Slots 2, 3, and 6 (three I/O slots) are used for SAS I/O modules for systems without
Extended Retention (ER).
Note
Slots 2, 3, 6, and 9 (four I/O slots) are for SAS I/O modules for systems with ER or
DD Cloud Tier software.
The table shows the I/O module slot assignments for the DD9500 and DD9800
systems. Each type of I/O module is restricted to certain slots.
The I/O module slot assignments for the DD9500 and DD9800 systems are the same.
Table 7 DD9500 and DD9800 I/O module slot assignments
Slot Base
configuratio
n
HA ER or DD Cloud
Tier
DD Cloud Tier
and HA
0 NVRAM NVRAM NVRAM NVRAM
1 Fibre Channel
(FC), Ethernet
or empty
Fibre Channel
(FC), Ethernet
or empty
Fibre Channel (FC),
Ethernet or empty
Fibre Channel (FC),
Ethernet or empty
2 SAS SAS SAS SAS
3 SAS SAS SAS SAS
4 FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
5 FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
6 SAS SAS SAS SAS
7 FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
8 FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
9 Not available
(contains a
filler)
Not available
(contains a
filler)
SAS SAS
10 FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
FC, Ethernet or
empty
11 FC, Ethernet or
empty
10 Gb optical
Ethernet for
interconnect
between the
FC, Ethernet or
empty
10 Gb optical
Ethernet for
interconnect
between the
Hardware Overview
28 Data Domain DD9500 and DD9800 Systems 6.1 Hardware Overview and Installation Guide