Enable administrative communication
For HA pairs, administrative communication must be enabled on both nodes.
The administrative interfaces are located on the management module on the rear of
the chassis. These interfaces are for management network traffic only. Do not use
these interfaces for data traffic.
1. Connect an administrative console to the serial port on the back panel of the
system.
2.
Note
You must have 115200 baud rate for the DD9500/DD9800 system to work
properly; 9600 baud rate will not work for the DD9500/DD9800 system.
Launch a terminal emulation program from your computer and configure the
following communication settings:
Table 27 Communications settings
Setting Value
Baud rate 115200
Data bits 8
Stop bits 1
Parity None
Flow control None
Emulation VT-100
3. Select Enter on your keyboard to activate the console.
Note
If you do not see the prompt on your terminal to log in, then complete Step 4.
4. In the front of the DD9500/DD9800 system, press the power button to turn the
power on the system. Check that the front blue power LED (with the circle with a
dot) also turns on.
Configure System For Use
86 Data Domain DD9500 and DD9800 Systems 6.1 Hardware Overview and Installation Guide