Dell Data Domain DD9500 - Standby Node Cabling Instructions

Dell Data Domain DD9500
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 21 Standby node cabling instructions (continued)
String
(Loop)
I/O - Port Shelf Port Length
a
3 I/O 6 - Port 0
B controller EXPANSION port of the highest
number shelf in V3
2M
4 I/O 3 - Port 3
A controller EXPANSION port of shelf V4.1
3M
4 I/O 2 - Port 2
B controller EXPANSION port of the highest
number shelf in V4
3M
5 I/O 3 - Port 2
A controller EXPANSION port of shelf V5.1
3M
5 I/O 9 - Port 2
B controller EXPANSION port of the highest
number shelf in V5
3M
6 I/O 2 - Port 3
A controller EXPANSION port of shelf V6.1
3M
6 I/O 6 - Port 3
B controller EXPANSION port of the highest
number shelf in V6
3M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power on
DD9500 /DD9800 with DD Cloud Tier (Single node or HA) 65