NOTE: When operating in the expanded temperature range, ambient temperature warnings maybe
reported on the LCD panel and in the System Event Log.
GUID-C7ED6A84-6734-4315-B167-92B007911598
Expanded operating temperature restrictions
Do not perform a cold startup below 5°C.
The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
160 W or higher wattage processor is not supported.
Redundant power supply units are required.
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
The 3.5-inch hard drive chassis supports a maximum of 120 W processor.
The 2.5-inch hard drive chassis supports a maximum of 145 W processor.
Only SSDs are allowed in the hard drive slots at the back of the 3.5-inch hard drive chassis.
Mid drive configurations, eight 3.5-inch and eighteen 1.8-inch SSD configurations are not supported.
GPU is not supported
Tape backup unit (TBU) is not supported.