Figure 12 Removing the system cover
Remove hard drive carrier from the mid hard drive tray
Before you begin
When a replacement hot swappable hard drive is installed and the system is
powered on, the hard drive automatically begins to rebuild. Ensure that the
replacement hard drive is blank or contains data that you wish to overwrite. Any
data on the replacement hard drive is immediately lost after the hard drive is
installed.
Mixing hard drive carriers from previous generations of PowerEdge servers is not
supported.
Procedure
1. Lift the hard drive carrier handle upward.
2. Press the release tab on the hard drive tray and lift the hard drive carrier handle
upward to disengage the hard drive from the backplane.
3. Hold the hard drive carrier handle and lift the hard drive carrier out of the hard
drive tray.
Remove and replace assemblies
26 Dell EMC Integrated Data Protection Appliance DP4400 2.4 Service Procedures Guide