EasyManua.ls Logo

Dell EMC Integrated Data Protection Appliance DP4400 - Remove the Rear Hard Drive Cage; Remove the Network Daughter Card

Dell EMC Integrated Data Protection Appliance DP4400
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 8 NIC indicator codes (continued)
Status Condition
Link indicator is blinking green and
activity is off
NIC identify is enabled through the NIC
configuration utility.
Remove the rear hard drive cage
The rear hard drive cage is removed to access the network daughter card.
Procedure
1. Disconnect all the cables from the rear hard drive backplane.
2. Using Phillips #2 screwdriver, loosen the screws that secure the hard drive cage
to the system.
3. Ensure that the clip on the right-hand side of the cage is not holding anything in
place.
4. Hold the hard drive cage by its sides, and lift it away from the system.
Figure 44 Removing the 3.5 inch hard drive rear cage
Remove the network daughter card
Procedure
1. Remove the NVMe card located above the network daughter card.
2. Using a Phillips #2 screwdriver, loosen the captive screws that secure the
network daughter card (NDC) to the system board.
3. Hold the NDC by the edges on either side of the touch points, and lift to remove
it from the connector on the system board.
Remove and replace assemblies
54 Dell EMC Integrated Data Protection Appliance DP4400 2.4 Service Procedures Guide

Table of Contents

Related product manuals