Figure 31 Target server
b. In Hardware view, right-click the target server and select Add Standby
Node.
c. In the Add Standby Node dialog box, enter a name for the node, select the
role that the source server had, and then click OK.
2. Right-click the target server and select Replace Cluster Member.
3. In the Replace Cluster Member dialog box, select the source server (the
faulted server) and then click OK.
4. When the cluster component has been successfully transferred from the source
to the target server, a success message is displayed. Click Close.
The Node Properties sheet displays the source server as a standby MDM and
the target server as an MDM in the cluster.
Managing System Objects