Syntax
scli --set_syslog_facility --remote_syslog_server_ip <IP> --
syslog_facility <FACILITY>
Actual command syntax is operating-system dependent. For more information, see 
“CLI basics”.
Description/Notes
Configures the facility field of the syslog events.
Parameters
Parameter Description
--remote_syslog_server_ip <IP> A comma-separated list of syslog server IP
addresses
--syslog_facility <FACILITY> Controls the facility field of the event (legal
values 0—23; default 16)
Example
scli --set_syslog_facility --remote_syslog_server_ip 
192.168.1.10,192.168.1.20 --syslog_facility 20
Event list
This section lists all VxFlex Ready Node events, grouped by the following categories:
l
Authentication
l
CLI commands
l
License and installation
l
MDM
l
SDC
l
SDS
l
Rebuild
Authentication
Authentication Failed
Parameter
Description
Name AUTHENTICATION_FAILED
Message Authentication failed for user U
Severity Warning
Description User entered the wrong password
System events
280 Dell EMC VxFlex Ready Node AMS User Guide