SDS Disconnected
Parameter Description
Name SDS_DISCONNECTED
Message SDS X (IP:Y; ID: Z) disconnected
Severity Error
Description SDS X (IP: Y; ID Z) has disconnected from the
MDM
Action Make sure that this is an expected event,
because otherwise this might be caused by a
hardware malfunction.
SDS Reconnected
Parameter Description
Name SDS_RECONNECTED
Message SDS X (IP:Y; ID: Z) reconnected
Severity Info
Description SDS X (IP: Y; ID Z) has reconnected to the
MDM. If this event appears multiple times
subsequently for the same SDS (and not
directly after SDS_DISCONNECTED), it can
indicate a bad network connection.
Action: Check network connections.
SDS Remove Done
Parameter
Description
Name SDS_REMOVE_DONE
Message SDS X (IP:Y; ID: Z) was removed successfully
Severity Info
Description The asynchronous process of removing an
SDS has completed.
Action None
Open SDS Device Failed
Parameter
Description
Name OPEN_SDS_DEVICE_FAILED