24 About Your System
E1711 PCI PERR B## D##
F##
The system BIOS has reported a
PCI parity error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.
Remove and reseat the PCIe
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 132.
PCI PERR Slot # The system BIOS has reported a
PCI parity error on a component
that resides in the specified PCIe
slot.
Reinstall the expansion-card cage.
See "Expansion-Card Cage" on
page 77.
If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 147.
E1712 PCI SERR B## D##
F##
The system BIOS has reported a
PCI system error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.
Remove and reseat the PCIe
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 132.
PCI SERR Slot # The system BIOS has reported a
PCI system error on a component
that resides in the specified slot.
Reinstall the expansion-card cage.
See "Expansion-Card Cage" on
page 77.
If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 147.
E1714 Unknown Err The system BIOS has determined
that there has been an error in the
system, but is unable to
determine its origin.
See "Getting Help" on page 147.
E171F PCIE Fatal Err
B## D## F##
The system BIOS has reported a
PCIe fatal error on a component
that resides in PCIe configuration
space at bus ##, device ##,
function ##.
Remove and reseat the PCIe
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 132.
PCIE Fatal Err
Slot #
The system BIOS has reported a
PCIe fatal error on a component
that resides in the specified slot.
Reinstall the expansion-card cage.
See "Expansion-Card Cage" on
page 77.
If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 147.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions

Table of Contents