Figure 107. Removing the M.2 NVMe SSD module
Next steps
1. Replace the M.2 NVMe SSD module.
Installing the M.2 NVMe SSD module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the BOSS-N1 module.
Steps
1. Align the M.2 NVMe SSD module at an angle with the BOSS-N1 card connector.
2. Insert the M.2 NVMe SSD module until it is firmly seated in the BOSS-N1 card connector.
3. Using the Phillips #1 screwdriver, secure the M.2 NVMe SSD module on the BOSS-N1 card with the M3 x 0.5 x 4.5 mm
screw.
Figure 108. Installing the M.2 NVMe SSD module