Troubleshooting
55
ERROR
CODE
DESC.
TROUBLESHOOTING /
CUSTOMER ACTIONS
E-0-1-2
Reverse
Polarity
Battery is connected the
wrong way around. Check the
battery connections. This error
automatically clears once the
condition has been corrected.
E-0-1-3
Battery
does
not take
current
Battery voltage is detected but
the charger is unable to charge
the battery. This can be due to
an electrical device connected
between the charger and the
battery, which passes through
voltage but not current. Verify
correct set up with OEM.
Table 5-2

Other manuals for Delta-q IC650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta-q IC650 and is the answer not in the manual?

Delta-q IC650 Specifications

General IconGeneral
Input Voltage85-265 VAC
Input Frequency45-65 Hz
Output Power650 W
Efficiency93%
Storage Temperature-40°C to +85°C
ProtectionOver-voltage, Over-temperature, Short-circuit
CommunicationCAN bus
Cooling MethodConvection
Output Voltage12-48 VDC