EasyManuals Logo

Delta-q IC650 Troubleshoot Manual

Delta-q IC650
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Troubleshooting
54
ERROR
CODE
DESC.
TROUBLESHOOTING /
CUSTOMER ACTIONS
E-0-0-1
E-0-2-1
High
Battery
Voltage
Error
Battery Voltage is too high
to charge. Check the battery
voltage and cable connections.
Check battery size and condition
(could be too full to charge). This
error automatically clears once
the condition has been corrected.
E-0-0-2
E-0-2-2
Low
Battery
Voltage
Battery Voltage is too low to
charge. Check the battery
voltage and cable connections.
Check battery size and condition.
This error automatically clears
once the condition has been
corrected.
E-0-0-3
Charge
Timeout
Charge Timeout caused by battery
pack not reaching required
voltage within safe time limit.
Charger output reduced due to
high temperatures. Possible
causes include poor battery
health, very deeply discharged
battery, poorly connected
battery, or extra loads. Possible
solutions include replacing the
battery pack, checking the DC
connections, disconnecting
parasitic loads, and operating
at lower ambient temperatures.
This error automatically clears
once the charger is reset by
cycling DC.
Table 5-1
10 MOST COMMON
ERROR CODES

Other manuals for Delta-q IC650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta-q IC650 and is the answer not in the manual?

Delta-q IC650 Specifications

General IconGeneral
Input Voltage85-265 VAC
Input Frequency45-65 Hz
Output Power650 W
Efficiency93%
Storage Temperature-40°C to +85°C
ProtectionOver-voltage, Over-temperature, Short-circuit
CommunicationCAN bus
Cooling MethodConvection
Output Voltage12-48 VDC

Related product manuals