ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-203
P5-85 ECME E-CAM: Number of Area
Address: 05AAH
05ABH
Operational
Interface
Panel / Software Communication
Related Section:
7.11
Default
0
Control
Mode
PR
Unit
-
Range 0 ~ (P5-821)
Data Size
16-bit
Format
Decimal
Settings
The area number of E-cam when E-cam engaged.
NOTE
A2L does not support E-Cam function.
P5-86
ECAX E-CAM: Master Axis Position
Address: 05ACH
05ADH
Operational
Interface
Panel / Software Communication
Related Section:
7.11
Default
0
Control
Mode
PR
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
The position counter of the E-Cam Master
NOTE
1. This parameter can be wrote when E-Cam stops (Please refer
toP5-88, X=0).
2. A2L does not support E-Cam function.