Chapter 7 Parameters ASDA-B2
7-58 Revision May, 2018
P2-18 DO1
DO1 Funcitonal Planning
Address: 0224H
0225H
Operation
Interface:
Panel/Software Communication
Related Section:
Table 7.2
Default: 101
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 0x013F
(The last two codes are DO code)
Data Size: 16-bit
Format: Hexadecimal
Settings:
Output funciton selection: Please refer to table 7.2.
Output contact: a or b contact
0: Set Set the output contact as normally closed (b contact)
1: Set the output contact as normally opened (a contact)
(P2-18 ~ P2-22 and P2-37) The setting value of function
programmed
When parameters are modified, please re-start the servo
drive to ensure it can work normally.
P2-19 DO2
DO2 Funcitonal Planning
Address: 0226H
0227H
Operation
Interface:
Panel/Software Communication
Related Section:
Table 7.2
Default: 103
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 0x013F
(The last two codes are DO code)
Data Size: 16-bit
Format: Hexadecimal
Settings: Please refer to the description of P2-18
Output function selection
Output contact
Not in use