Chapter 3 Wiring ASDA-B2
3-28 Revision May, 2018
Pulse command can be input by the way of open-collector or Line driver. The maximum
input pulse of Line driver is 500 kpps and 200 kpps for open-collector.
C3-1: The source of pulse input is open-collector NPN equipment which applies the
internal power of the servo drive.
DC24V
Approx.
2KΩ
75Ω
75Ω
75Ω
2KΩ
Max. input pulse
frequency is 200Kpps
Max. input pulse
frequency is 200Kpps
75Ω
SG
COM-
/SIGN
/PULSE
PULL_HI
VDD
17
35
14
37
41
Servo DriveController
2KΩ
2KΩ
C3-2: The source of pulse input is open-collector PNP equipment which applies the
internal power of the servo drive.