Chapter 7 Parameters  ASDA-B2 
7-82  Revision May, 2018 
P3-03   
FLT  Communication Error Disposal 
Address: 0306H 
0307H 
 
Operation 
Interface: 
Panel / Software  Communication 
Related Section:   
8.2 
 
Default: 0 
 
Control 
Mode: 
ALL 
 
Unit: N/A 
 
Range: 0 ~ 1 
 
Data Size: 16-bit 
 
Format: Hexadecimal 
Settings: The definition of the setting value is as the following: 
0: Warning and keeps running   
1: Warning and stops deceleration (The deceleration time is set to 
parameter P1-32) 
 
P3-04   
CWD  Communication Time Out 
Address: 0308H 
0309H 
 
Operation 
Interface: 
Panel / Software  Communication 
Related Section:   
8.2 
 
Default: 0 
 
Control 
Mode: 
ALL 
 
Unit: sec 
 
Range: 0 ~ 20 
 
Data Size: 16-bit 
 
Format: Decimal 
Settings: If the setting value is not 0, enable communication timeout 
immediately. If it is set to 0, disable the function. 
 
P3-05    CMM  Communication Mechanism 
Address: 030AH 
030BH 
 
Operation 
Interface: 
Panel / Software  Communication 
Related Section:   
8.2 
 
Default: 0 
 
Control 
Mode: 
ALL 
 
Unit: N/A 
 
Range: 0x00 ~ 0x01 
 
Data Size: 16-bit 
 
Format: Hexadecimal 
Settings: RS-232 via MOBUS communication or communicate with 
ASDA-Soft 
  RS-232 Communication format 
0: RS-232/RS485 via Modbus communication 
1: RS-232 upon ASDA-Soft software