Chapter 7 Parameters  ASDA-B2 
7-106  Revision May, 2018 
Monitoring variables are described in the following table by the code sequence: 
Code 
Variable name / 
property 
Description 
000 (00h) 
Feedback position 
(PUU) B 
Current feedback position of the motor encoder.   
Unit: Pulse of User Unit (PUU). 
001 (01h) 
Position command 
(PUU) B 
Current coordinate of the Position command.   
Unit: Pulse of User Unit (PUU). 
PT mode: number of pulse commands received by the 
servo drive. 
PR mode: absolute coordinates of the Position 
command. 
002 (02h) 
Position deviation 
(PUU) B 
Deviation between the Position command and the 
feedback position. Unit: Pulse of User Unit (PUU). 
003 (03h) 
Feedback position 
(pulse) B 
Current feedback position of the motor encoder.   
Unit: Encoder unit (pulse). 
004 (04h) 
Position command 
(pulse) B 
Current coordinate of the Position command.   
Unit: Encoder unit (pulse). 
This is the command after passing E-Gear. 
005 (05h) 
Position deviation 
(pulse) B 
Deviation between the Position command and the 
feedback position. Unit: Encoder unit (pulse). 
006 (06h) 
Pulse command 
frequency B 
Frequency of the pulse command received by the 
servo drive. Unit: Kpps.   
Applicable to PT / PR mode. 
007 (07h) 
Speed feedback 
B  D1  Dec 
Current motor speed. Unit: 0.1 rpm. 
The low-pass filter has been applied to this value to 
make it more stable. 
008 (08h) 
Speed command 
(analog) 
B  D2  Dec 
Speed command from the analog channel.   
Unit: 0.01 Volt. 
009 (09h) 
Speed command 
(integrated) B 
Integrated Speed command. Unit: 1 rpm. 
Source includes analog, register, or position loop. 
010 (0Ah) 
Torque command 
(analog) 
B  D2  Dec 
Torque command from the analog channel.   
Unit: 0.01 Volt. 
011 (0Bh) 
Torque command 
(integrated) B 
Integrated Torque command. Unit: percentage (%). 
Source includes analog, register, or speed loop. 
012 
(0Ch) 
Average load rate B 
Average load rate from the servo drive.   
Unit: percentage (%). 
013 
(0Dh) 
Peak load rate B 
Maximum load rate from the servo drive.   
Unit: percentage (%). 
014 (0Eh)  DC Bus voltage B  Rectified capacitor voltage. Unit: Volt. 
015 (0Fh) 
Load inertia ratio 
B  D1  Dec 
Ratio of the load inertia to the motor inertia.   
Unit: 0.1 times. 
016 (10h) 
IGBT temperature 
B 
Temperature of IGBT. Unit: °C.