Chapter 9 Troubleshooting  ASDA-B2 
9-16     Revision May, 2018 
AL019 
Serial communication error  Turn DI.ARST on to clear the alarm 
AL020 
Serial communication time out  Turn DI.ARST on to clear the alarm 
AL022 
Main circuit power leak phase  Turn DI.ARST on to clear the alarm 
AL023 
Early warning for overload  Turn DI.ARST on to clear the alarm 
AL024 
Encoder initial magnetic field error 
The alarm can be cleared after  
re-power on. 
AL025 
The internal of the encoder is in error 
The alarm can be cleared after  
re-power on. 
AL026 
The encoder is in error 
The alarm can be cleared after  
re-power on. 
AL027 
The internal of the encoder is in error 
The alarm can be cleared after  
re-power on. 
AL028 
The internal of the encoder is in error 
The alarm can be cleared after  
re-power on. 
AL029 
The internal of the encoder is in error 
The alarm can be cleared after  
re-power on. 
AL030 
Motor crash error 
Turn DI.ARST on to clear the alarm 
AL031 
Incorrect wiring of the motor power 
line U, V, W, GND 
The alarm can be cleared after  
re-power on. 
AL035 
Encoder temperature exceeds the 
protective range 
The alarm can be cleared after  
re-power on. 
AL048 
Excessive encoder output error  Turn DI.ARST on to clear the alarm 
AL067 
Encoder temperature warning 
The alarm will be cleared when the 
temperature back to normal. 
AL083 
Servo drive outputs excessive current  Turn DI.ARST on to clear the alarm 
AL085 
Regeneration error  Turn DI.ARST on to clear the alarm 
AL099 
DSP firmware upgrade 
Firstly set P2-08 to 30. Then set it to 
28. And the alarm will be cleared 
after re-power on. 
AL555 
DSP processing error  N/A 
AL880 
DSP processing error  N/A