Array insulation resistance
detection
500 kΩ (> V
MAX
PV/30 mA)
Continuous residual current
threshold value
250 mA (I
LIMIT
: 300 mA)
Continuous residual current trip
time
180 ms(T
LIMIT
: 300 ms)
Sudden residual current threshold
value
20 mA(I
LIMIT
: 30 mA) 50 mA (I
LIMIT
: 60 mA) 130 mA (I
LIMIT
: 150 mA)
Sudden residual current trip time
180 ms (T
LIMIT
: 300 ms) 50 ms (T
LIMIT
: 150 ms) 0 ms (T
LIMIT
: 40 ms)
M5-TL-AU
Nominal power 3000 W 4000 W 5000 W
Maximum output power 3000 W 4000 W 5000 W
Maximum output power
3000 VA 4000 VA 5000 VA
Operating voltage range
180~275 V
Rated output voltage
230 V
Max continuous current 16A 20A 24 A(21.7 A for AU)
Maximum output overcurrent
protection
25 A 30 A 35 A
Maximum inrush current
5 A 5 A 5 A
Maximum output fault current
18 A 24 A 32 A
Nominal frequency
50 Hz
Operating frequency range
45.0 ~ 55.0 Hz
Standby power consumption
< 10 W
Night consumption
< 1 W
iTHD @ nominal power
< 3%
Acoustic noise
40 dB
Overvoltage category
III
Power factor @ nominal power
> 0.99
Adjustable power factor range
0.80i ~ 0.80c
Model
M3-TL M4-TL M5-TL
PV & GRID CONNECTION