Communication Module DVPSCM12/52-SL
DVP-PLC Operation Manual
56
Checksum:
End word:
Respond with the full record.
Start word+Length+Length (repeat)+Start word+Device address (IA)+Function
code (FF)+Parameter index (PI)+Data block (DB)+Checksum (CS)+End marker
Æ 68h + (Null) + (Null) + 68h + D0 + (Null) + D1 + D100 + (the content gotten from adding from IA to the
end) + 16h
Start word:
Length-Length (two words): Ignore the
two words.