The injection steps are as follows:
Step 1: Remove the outer cover of the cylinder block wire cover
Step 2: Unscrew the plug of the oil hole on the cylinder body
Step 3: Pull out the electric cylinder until you see the nozzle in the oil hole
Step 4: Stop the motor and cut off the power
Step 5: Inject grease into the nozzle
Step 6: Screw on the plug
Step 7: Put the outer cover of the cylinder block wire cover on
Step 8: Turn on the power and allow the servo electric cylinder to fully cycle 2 to 3 times